High-Pressure Test Center
Key parameters
- max. working pressure: 550 bar / 7980 psi
- experimental volume: 38 liter / 10 gal (DL1), 99 liter /26.2 gal (DL2)
- zusätzliche Medienspeicher: 40 l, 1 l, 3x 250 ml
- temperature range: 2 to 50 °C
- fluid, gaseous and solid test media
- isobaric/decompression-free media exchange
- mechanical, electrical, optical and hydraulical access points
- measurement equipment (standard, others possible): pressure, temperature, mass/volume flow (liquid and gaseous), density, HD video
- experiments performed: deep-sea simulation, hydrodynamic investigations of natural gas and crude oil, clathrate hydrare synthesis and analysis, structural and functional testing of tools and components under external/internal pressur