Prof. Dr.-Ing. Tobias Knopp

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 209
22529 Hamburg
- Postanschrift -

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 56794
Fax: 040 / 7410 45811
E-Mail: t.knopp(at)uke.de
E-Mail: tobias.knopp(at)tuhh.de
ORCID: https://orcid.org/0000-0002-1589-8517

 

Roles

  • Head of the Institute for Biomedical Imaging
  • Editor-in-chief of the International Journal on Magnetic Particle Imaging (IJMPI)

Consulting Hours

  • On appointment

Research Interests

  • Tomographic Imaging
  • Image Reconstruction
  • Signal- and Image Processing
  • Magnetic Particle Imaging

Curriculum Vitae

Tobias Knopp received his Diplom degree in computer science in 2007 and his PhD in 2010, both from the University of Lübeck with highest distinction. For his PHD on the tomographic imaging method Magnetic Particle Imaging (MPI) he was awarded with the Klee award from the DGBMT (VDE) in 2011. From 2010 until 2011 he led the MAPIT project at the University of Lübeck and published the first scientific book on MPI. In 2011 he joined Bruker Biospin to work on the first commercially available MPI system. From 2012 until 2014 he worked at Thorlabs in the field of Optical Coherence Tomography (OCT) as a software developer. In 2014 he has been appointed as Professor for experimental Biomedical Imaging at the University Medical Center Hamburg-Eppendorf and the Hamburg University of Technology.

Publications

[183661]
Title: Saline bolus for negative contrast perfusion imaging in magnetic particle imaging.
Written by: F. Mohn, M. Exner, P. Szwargulski, M. Möddel, T. Knopp, and M. Graeser
in: <em>Physics in Medicine & Biology</em>. aug (2023).
Volume: <strong>68</strong>. Number: (17),
on pages: 5026
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN: 0031-9155, 1361-6560
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1088/1361-6560/ace309
URL:
ARXIVID:
PMID:

Note: article, openaccess

Abstract: Magnetic Particle Imaging is capable to measure the spatial distribution of magnetic nanoparticles with high temporal resolution. As a quantitative tracer based imaging method, the signal is linear in the tracer concentration for any location that contains nanoparticles and zero in the surrounding tissue which does not provide any intrinsic signal. After tracer injection, the concentration over time (positive contrast) can be utilized to calculate dynamic diagnostic parameters like perfusion parameters in vessels and organs, which are an important tool in medical diagnosis. Every acquired perfusion image thus requires a new bolus of tracer with a sufficiently large iron dose to be visible above the background. We propose a method, where a bolus of physiological saline solution without any particles (negative contrast) displaces the remaining steady state concentration which in turn contributes to the image contrast. Perfusion parameters are calculated based on the time response of this negative bolus and compared to a positive bolus. Results from phantom experiments show that normalized signals from positive and negative boli are concurrent and deviations of calculated perfusion maps are low. Our method opens up the possibility to increase the total monitoring time of a future patient by utilizing a positive-negative contrast sequence, while minimizing the iron dose per acquired image.