Dr.-Ing. Matthias Gräser

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 212
22529 Hamburg

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 25812
E-Mail: matthias.graeser(at)tuhh.de
E-Mail: ma.graeser(at)uke.de

Research Interests

  • Magnetic Particle Imaging
  • Low Noise Electronics
  • Inductive Sensors
  • Passive Electrical Devices

Curriculum Vitae

Matthias Gräser submitted his Dr.-Ing. thesis in january 2016 at the institute of medical engineering (IMT) at the university of Lübeck and is now working as a Research Scientist at the institute for biomedical imaging (IBI) at the technical university in Hamburg, Germany.  Here he develops concepts for Magnetic-Particle-Imaging (MPI) devices. His main aim is to improve the sensitivity of the imageing devices and improve resolution and application possibilities of MPI technology.

In 2011 Matthias Gräser started to work at the IMT as a Research Associate in the Magnetic Particle Imaging Technology (MAPIT) project. In this project he devolped the analog signal chains for a rabbit sized field free line imager. Additionally he developed a two-dimensional Magnetic-Particle-Spectrometer. This device can apply various field sequences and measure the particle response with a very high signal-to-noise ratio (SNR).

The dynamic behaviour of magnetic nanoparticles is still not fully understood. Matthias Gräser investigated the particle behaviour by modeling the particle behaviour with stochastic differential equations. With this model it is possible to simulate the impact of several particle parameters and field sequences on the particle response .

In 2010 Matthias Gräser finished his diploma at the Karlsruhe Institue of Technology (KIT). His diploma thesis investigated the nerve stimulation of magnetic fields in the range from 4 kHz to 25 kHz.

Journal Publications

Journal Publications

[76904]
Title: Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil.
Written by: M. Graeser, T. Knopp, P. Szwargulski, T. Friedrich, A. von Gladiss, M. Kaul, K. M. Krishnan, H. Ittrich, G. Adam, and T. M. Buzug
in: <em>Scientific Reports</em>. (2017).
Volume: <strong>7</strong>. Number:
on pages: 6872
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1038/s41598-017-06992-5
URL: https://doi.org/10.1038/s41598-017-06992-5
ARXIVID:
PMID:

[www] [BibTex]

Note: article, openaccess

Abstract: Superparamagnetic iron-oxide nanoparticles can be used in medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first has been proven in the assessment of dynamic processes like cardiac imaging, it is unknown how far the detection limit of MPI can be lowered. Within this work, we will present a highly sensitive gradiometric receive-coil unit combined with a noise-matching network tailored for the imaging of mice. The setup is capable of detecting 5 ng of iron in-vitro with an acquisition time of 2.14 sec. In terms of iron concentration we are able to detect 156 μg/L marking the lowest value that has been reported for an MPI scanner so far. In-vivo MPI mouse images of a 512 ng bolus and a 21.5 ms acquisition time allow for capturing the flow of an intravenously injected tracer through the heart of a mouse. Since it has been rather difficult to compare detection limits across MPI publications we propose guidelines to improve the comparability of future MPI studies.

Conference Proceedings

Conference Proceedings

[76904]
Title: Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil.
Written by: M. Graeser, T. Knopp, P. Szwargulski, T. Friedrich, A. von Gladiss, M. Kaul, K. M. Krishnan, H. Ittrich, G. Adam, and T. M. Buzug
in: <em>Scientific Reports</em>. (2017).
Volume: <strong>7</strong>. Number:
on pages: 6872
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1038/s41598-017-06992-5
URL: https://doi.org/10.1038/s41598-017-06992-5
ARXIVID:
PMID:

[www] [BibTex]

Note: article, openaccess

Abstract: Superparamagnetic iron-oxide nanoparticles can be used in medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first has been proven in the assessment of dynamic processes like cardiac imaging, it is unknown how far the detection limit of MPI can be lowered. Within this work, we will present a highly sensitive gradiometric receive-coil unit combined with a noise-matching network tailored for the imaging of mice. The setup is capable of detecting 5 ng of iron in-vitro with an acquisition time of 2.14 sec. In terms of iron concentration we are able to detect 156 μg/L marking the lowest value that has been reported for an MPI scanner so far. In-vivo MPI mouse images of a 512 ng bolus and a 21.5 ms acquisition time allow for capturing the flow of an intravenously injected tracer through the heart of a mouse. Since it has been rather difficult to compare detection limits across MPI publications we propose guidelines to improve the comparability of future MPI studies.