Dr.-Ing. Matthias Gräser

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 212
22529 Hamburg

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 25812
E-Mail: matthias.graeser(at)tuhh.de
E-Mail: ma.graeser(at)uke.de

Research Interests

  • Magnetic Particle Imaging
  • Low Noise Electronics
  • Inductive Sensors
  • Passive Electrical Devices

Curriculum Vitae

Matthias Gräser submitted his Dr.-Ing. thesis in january 2016 at the institute of medical engineering (IMT) at the university of Lübeck and is now working as a Research Scientist at the institute for biomedical imaging (IBI) at the technical university in Hamburg, Germany.  Here he develops concepts for Magnetic-Particle-Imaging (MPI) devices. His main aim is to improve the sensitivity of the imageing devices and improve resolution and application possibilities of MPI technology.

In 2011 Matthias Gräser started to work at the IMT as a Research Associate in the Magnetic Particle Imaging Technology (MAPIT) project. In this project he devolped the analog signal chains for a rabbit sized field free line imager. Additionally he developed a two-dimensional Magnetic-Particle-Spectrometer. This device can apply various field sequences and measure the particle response with a very high signal-to-noise ratio (SNR).

The dynamic behaviour of magnetic nanoparticles is still not fully understood. Matthias Gräser investigated the particle behaviour by modeling the particle behaviour with stochastic differential equations. With this model it is possible to simulate the impact of several particle parameters and field sequences on the particle response .

In 2010 Matthias Gräser finished his diploma at the Karlsruhe Institue of Technology (KIT). His diploma thesis investigated the nerve stimulation of magnetic fields in the range from 4 kHz to 25 kHz.

Journal Publications

Journal Publications

[190568]
Title: Real-Time Multi-Contrast Magnetic Particle Imaging for the Detection of Gastrointestinal Bleeding.
Written by: F. Mohn, P. Szwargulski, M. G. Kaul, M. Graeser, T. Mummert, K. M. Krishnan, T. Knopp, G. Adam, J. Salamon and C. Riedel
in: <em>Scientific Reports</em>. (2023).
Volume: <strong>13</strong>. Number: (1),
on pages: 22976
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1038/s41598-023-50041-3
URL:
ARXIVID:
PMID:

[BibTex]

Note: article, openaccess

Abstract: Gastrointestinal bleeding, as a potentially life-threatening condition, is typically diagnosed by radiation-based imaging modalities like computed tomography or more invasively catheter-based angiography. Endoscopy enables examination of the upper gastrointestinal tract and the colon but not of the entire small bowel. Magnetic Particle Imaging (MPI) enables non-invasive, volumetric imaging without ionizing radiation. The aim of this study was to evaluate the feasibility of detecting gastrointestinal bleeding by single- and multi-contrast MPI using human-sized organs. A 3D-printed small bowel phantom and porcine small bowel specimens were prepared with a defect within the bowel wall as the source of a bleeding. For multi-contrast MPI, the bowel lumen was filled with an intestinal tracer representing an orally administered tracer. MPI was performed to evaluate the fluid exchange between the vascular compartment of the bowel wall and the lumen while a blood pool tracer was applied. Leakage of the blood pool tracer was observed to the bowel lumen. Multi-contrast MPI enabled co-registration of both tracers at the same location within the bowel lumen indicating gastrointestinal bleeding. Single- and multi-contrast MPI are feasible to visualize gastrointestinal bleeding. Therefore, MPI might emerge as a useful tool for radiation-free detection of bleeding within the entire gastrointestinal tract.

Conference Proceedings

Conference Proceedings

[190568]
Title: Real-Time Multi-Contrast Magnetic Particle Imaging for the Detection of Gastrointestinal Bleeding.
Written by: F. Mohn, P. Szwargulski, M. G. Kaul, M. Graeser, T. Mummert, K. M. Krishnan, T. Knopp, G. Adam, J. Salamon and C. Riedel
in: <em>Scientific Reports</em>. (2023).
Volume: <strong>13</strong>. Number: (1),
on pages: 22976
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1038/s41598-023-50041-3
URL:
ARXIVID:
PMID:

[BibTex]

Note: article, openaccess

Abstract: Gastrointestinal bleeding, as a potentially life-threatening condition, is typically diagnosed by radiation-based imaging modalities like computed tomography or more invasively catheter-based angiography. Endoscopy enables examination of the upper gastrointestinal tract and the colon but not of the entire small bowel. Magnetic Particle Imaging (MPI) enables non-invasive, volumetric imaging without ionizing radiation. The aim of this study was to evaluate the feasibility of detecting gastrointestinal bleeding by single- and multi-contrast MPI using human-sized organs. A 3D-printed small bowel phantom and porcine small bowel specimens were prepared with a defect within the bowel wall as the source of a bleeding. For multi-contrast MPI, the bowel lumen was filled with an intestinal tracer representing an orally administered tracer. MPI was performed to evaluate the fluid exchange between the vascular compartment of the bowel wall and the lumen while a blood pool tracer was applied. Leakage of the blood pool tracer was observed to the bowel lumen. Multi-contrast MPI enabled co-registration of both tracers at the same location within the bowel lumen indicating gastrointestinal bleeding. Single- and multi-contrast MPI are feasible to visualize gastrointestinal bleeding. Therefore, MPI might emerge as a useful tool for radiation-free detection of bleeding within the entire gastrointestinal tract.