Dr.-Ing. Matthias Gräser

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 212
22529 Hamburg

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 25812
E-Mail: matthias.graeser(at)tuhh.de
E-Mail: ma.graeser(at)uke.de

Research Interests

  • Magnetic Particle Imaging
  • Low Noise Electronics
  • Inductive Sensors
  • Passive Electrical Devices

Curriculum Vitae

Matthias Gräser submitted his Dr.-Ing. thesis in january 2016 at the institute of medical engineering (IMT) at the university of Lübeck and is now working as a Research Scientist at the institute for biomedical imaging (IBI) at the technical university in Hamburg, Germany.  Here he develops concepts for Magnetic-Particle-Imaging (MPI) devices. His main aim is to improve the sensitivity of the imageing devices and improve resolution and application possibilities of MPI technology.

In 2011 Matthias Gräser started to work at the IMT as a Research Associate in the Magnetic Particle Imaging Technology (MAPIT) project. In this project he devolped the analog signal chains for a rabbit sized field free line imager. Additionally he developed a two-dimensional Magnetic-Particle-Spectrometer. This device can apply various field sequences and measure the particle response with a very high signal-to-noise ratio (SNR).

The dynamic behaviour of magnetic nanoparticles is still not fully understood. Matthias Gräser investigated the particle behaviour by modeling the particle behaviour with stochastic differential equations. With this model it is possible to simulate the impact of several particle parameters and field sequences on the particle response .

In 2010 Matthias Gräser finished his diploma at the Karlsruhe Institue of Technology (KIT). His diploma thesis investigated the nerve stimulation of magnetic fields in the range from 4 kHz to 25 kHz.

Journal Publications

Journal Publications

[76885]
Title: Magnetic particle imaging: introduction to imaging and hardware realization.
Written by: T. M. Buzug, G. Bringout, M. Erbe, K. Gräfe, M. Graeser, M. Grüttner, A. Halkola, T. F. Sattel, W. Tenner, H. Wojtczyk, J. Haegele, F. M. Vogt, J. Barkhausen, and K. Lüdtke-\-Buzug
in: <em>Zeitschrift Für Medizinische Physik</em>. (2012).
Volume: <strong>22</strong>. Number: (4),
on pages: 323--334
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1016/j.zemedi.2012.07.004
URL:
ARXIVID:
PMID: 22909418

[BibTex] [pmid]

Note: article

Abstract: {Magnetic Particle Imaging} ({MPI}) is a recently invented tomographic imaging method that quantitatively measures the spatial distribution of a tracer based on magnetic nanoparticles. The new modality promises a high sensitivity and high spatial as well as temporal resolution. There is a high potential of {MPI} to improve interventional and image-guided surgical procedures because, today, established medical imaging modalities typically excel in only one or two of these important imaging properties. {MPI} makes use of the non-linear magnetization characteristics of the magnetic nanoparticles. For this purpose, two magnetic fields are created and superimposed, a static selection field and an oscillatory drive field. If superparamagnetic iron-oxide nanoparticles ({SPIOs}) are subjected to the oscillatory magnetic field, the particles will react with a non-linear magnetization response, which can be measured with an appropriate pick-up coil arrangement. Due to the non-linearity of the particle magnetization, the received signal consists of the fundamental excitation frequency as well as of harmonics. After separation of the fundamental signal, the nanoparticle concentration can be reconstructed quantitatively based on the harmonics. The spatial coding is realized with the static selection field that produces a field-free point, which is moved through the field of view by the drive fields. This article focuses on the frequency-based image reconstruction approach and the corresponding imaging devices while alternative concepts like x-space {MPI} and field-free line imaging are described as well. The status quo in hardware realization is summarized in an overview of {MPI} scanners.

Conference Proceedings

Conference Proceedings

[76885]
Title: Magnetic particle imaging: introduction to imaging and hardware realization.
Written by: T. M. Buzug, G. Bringout, M. Erbe, K. Gräfe, M. Graeser, M. Grüttner, A. Halkola, T. F. Sattel, W. Tenner, H. Wojtczyk, J. Haegele, F. M. Vogt, J. Barkhausen, and K. Lüdtke-\-Buzug
in: <em>Zeitschrift Für Medizinische Physik</em>. (2012).
Volume: <strong>22</strong>. Number: (4),
on pages: 323--334
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.1016/j.zemedi.2012.07.004
URL:
ARXIVID:
PMID: 22909418

[BibTex] [pmid]

Note: article

Abstract: {Magnetic Particle Imaging} ({MPI}) is a recently invented tomographic imaging method that quantitatively measures the spatial distribution of a tracer based on magnetic nanoparticles. The new modality promises a high sensitivity and high spatial as well as temporal resolution. There is a high potential of {MPI} to improve interventional and image-guided surgical procedures because, today, established medical imaging modalities typically excel in only one or two of these important imaging properties. {MPI} makes use of the non-linear magnetization characteristics of the magnetic nanoparticles. For this purpose, two magnetic fields are created and superimposed, a static selection field and an oscillatory drive field. If superparamagnetic iron-oxide nanoparticles ({SPIOs}) are subjected to the oscillatory magnetic field, the particles will react with a non-linear magnetization response, which can be measured with an appropriate pick-up coil arrangement. Due to the non-linearity of the particle magnetization, the received signal consists of the fundamental excitation frequency as well as of harmonics. After separation of the fundamental signal, the nanoparticle concentration can be reconstructed quantitatively based on the harmonics. The spatial coding is realized with the static selection field that produces a field-free point, which is moved through the field of view by the drive fields. This article focuses on the frequency-based image reconstruction approach and the corresponding imaging devices while alternative concepts like x-space {MPI} and field-free line imaging are described as well. The status quo in hardware realization is summarized in an overview of {MPI} scanners.