Marija Boberg, M. Sc.

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 213
22529 Hamburg
- Postanschrift -

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 25813
E-Mail: m.boberg(at)uke.de
E-Mail: marija.boberg(at)tuhh.de
ORCID: https://orcid.org/0000-0003-3419-7481

Research Interests

  • Magnetic Particle Imaging
  • Image Reconstruction
  • Magnetic Fields

Curriculum Vitae

Marija Boberg studied mathematics at the University of Paderborn between 2011 and 2017. She received her master's degree with her thesis on "Analyse von impliziten Lösern für Differential-Algebraische Gleichungssysteme unter Verwendung von Algorithmischem Differenzieren". Currently, she is a PhD student in the group of Tobias Knopp for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf and the Hamburg University of Technology.

Journal Publications

[183663]
Title: The pitfalls of receive path calibration.
Written by: F. Thieben, T. Knopp, M. Boberg, F. Foerger, M. Graeser, and M. Möddel
in: <em>International Journal on Magnetic Particle Imaging IJMPI</em>. mar (2023).
Volume: <strong>9</strong>. Number: (1 Suppl 1),
on pages:
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI:
URL: https://www.journal.iwmpi.org/index.php/iwmpi/article/view/606
ARXIVID:
PMID:

[www]

Note: inproceedings, instrumentation

Abstract: In Magnetic Particle Imaging (MPI) and magnetic particle spectroscopy (MPS) magnetic nanoparticles (MNPs) are exposed to static and dynamic fields. These cause a dynamic magnetization response that is typically measured with inductive coils. The signal acquisition generally occurs in parallel with the excitation. This has the consequence that the excitation field couples into each receive path. The feed-through signal is commonly dampened by advanced passive filtering, at the cost of a distorted particle signal. Consequently, the measurement signals of different MPI or MPS devices will differ, even if the underlying magnetization response of the MNPs is the same. Receive path calibration can be used to address this issue by reverting these distortions and transforming the signal into a device independent domain. The authors of this abstract studied a general calibration procedure for multi-channel, non-orthogonal and non-homogeneous receive coils along with an analytical calibration model. Furthermore, method and model uncertainties were investigated and a systematic model error that had not been accounted for in previous calibration methods has been identified. This systematic model error could be attributed to the approximation of the mutual inductance between receive and calibration coil and it becomes non-negligible in experimental setups with small inductive receivers. Suggestionswere made for estimating and reducing its influence. Finally, the method was used to calibrate the receive path of an MPS system and of a multi-channel, non-orthogonal MPI receive coil setup.

Conference Proceedings

[183663]
Title: The pitfalls of receive path calibration.
Written by: F. Thieben, T. Knopp, M. Boberg, F. Foerger, M. Graeser, and M. Möddel
in: <em>International Journal on Magnetic Particle Imaging IJMPI</em>. mar (2023).
Volume: <strong>9</strong>. Number: (1 Suppl 1),
on pages:
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI:
URL: https://www.journal.iwmpi.org/index.php/iwmpi/article/view/606
ARXIVID:
PMID:

[www] [BibTex]

Note: inproceedings, instrumentation

Abstract: In Magnetic Particle Imaging (MPI) and magnetic particle spectroscopy (MPS) magnetic nanoparticles (MNPs) are exposed to static and dynamic fields. These cause a dynamic magnetization response that is typically measured with inductive coils. The signal acquisition generally occurs in parallel with the excitation. This has the consequence that the excitation field couples into each receive path. The feed-through signal is commonly dampened by advanced passive filtering, at the cost of a distorted particle signal. Consequently, the measurement signals of different MPI or MPS devices will differ, even if the underlying magnetization response of the MNPs is the same. Receive path calibration can be used to address this issue by reverting these distortions and transforming the signal into a device independent domain. The authors of this abstract studied a general calibration procedure for multi-channel, non-orthogonal and non-homogeneous receive coils along with an analytical calibration model. Furthermore, method and model uncertainties were investigated and a systematic model error that had not been accounted for in previous calibration methods has been identified. This systematic model error could be attributed to the approximation of the mutual inductance between receive and calibration coil and it becomes non-negligible in experimental setups with small inductive receivers. Suggestionswere made for estimating and reducing its influence. Finally, the method was used to calibrate the receive path of an MPS system and of a multi-channel, non-orthogonal MPI receive coil setup.