Florian Thieben, M.Sc.

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 202
22529 Hamburg
- Postanschrift -

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 56355
E-Mail: f.thieben(at)uke.de
E-Mail: florian.thieben(at)tuhh.de
ORCID: https://orcid.org/0000-0002-2890-5288

Research Interests

  • Magnetic Particle Imaging
  • Low noise electronics
  • Inductive sensors and filters
  • Magnetic Particle Imaging scanner characterization

Curriculum Vitae

Florian Thieben works as an electrical engineer in the group of Tobias Knopp for experimental Biomedical Imaging at the University Medical Center Hamburg-Eppendorf and the Hamburg University of Technology. In 2017 he graduated with a master's degree thesis on Entwicklung eines kompakten Magnet Partikel Spektrometers mit gradiometrischer Empfangskette".

Journal Publications

[191176]
Title: Experimental Parameter Calibration of the Scanner Model for Model-Based MPI.
Written by: F. Thieben, H. Albers, F. Mohn, F. Foerger, M. Boberg, K. Scheffler, M. Möddel, T. Kluth, and T. Knopp
in: <em>International Journal on Magnetic Particle Imaging</em>. mar (2024).
Volume: <strong>10</strong>. Number: (1 Suppl 1),
on pages: 1-4
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.18416/IJMPI.2024.2403025
URL: https://www.journal.iwmpi.org/index.php/iwmpi/article/view/722
ARXIVID:
PMID:

[www]

Note: inproceedings

Abstract: Model-based reconstruction is still one of the key challenges in magnetic particle imaging (MPI) when using multi-dimensional Lissajous-type excitation. Besides an appropriate particle model, the model of the MPI system for signal generation and reception has a major impact on the modeled system matrix. We outline the influence of the latter MPI scanner parameters on the system matrix pattern and review methods to calibrate each parameter.

Conference Proceedings

[191176]
Title: Experimental Parameter Calibration of the Scanner Model for Model-Based MPI.
Written by: F. Thieben, H. Albers, F. Mohn, F. Foerger, M. Boberg, K. Scheffler, M. Möddel, T. Kluth, and T. Knopp
in: <em>International Journal on Magnetic Particle Imaging</em>. mar (2024).
Volume: <strong>10</strong>. Number: (1 Suppl 1),
on pages: 1-4
Chapter:
Editor:
Publisher:
Series:
Address:
Edition:
ISBN:
how published:
Organization:
School:
Institution:
Type:
DOI: 10.18416/IJMPI.2024.2403025
URL: https://www.journal.iwmpi.org/index.php/iwmpi/article/view/722
ARXIVID:
PMID:

[www] [BibTex]

Note: inproceedings

Abstract: Model-based reconstruction is still one of the key challenges in magnetic particle imaging (MPI) when using multi-dimensional Lissajous-type excitation. Besides an appropriate particle model, the model of the MPI system for signal generation and reception has a major impact on the modeled system matrix. We outline the influence of the latter MPI scanner parameters on the system matrix pattern and review methods to calibrate each parameter.