Fabian Mohn, M.Sc.

Universitätsklinikum Hamburg-Eppendorf (UKE)
Sektion für Biomedizinische Bildgebung
Lottestraße 55
2ter Stock, Raum 203
22529 Hamburg
- Postanschrift -

Technische Universität Hamburg (TUHH)
Institut für Biomedizinische Bildgebung
Gebäude E, Raum 4.044
Am Schwarzenberg-Campus 3
21073 Hamburg

Tel.: 040 / 7410 25812
E-Mail: f.mohn(at)uke.de
E-Mail: fabian.mohn(at)tuhh.de
ORCID:  https://orcid.org/0000-0002-9151-9929

Research Interests

  • (arbitrary waveform) Magnetic Particle Imaging
  • inductive sensors, filters and resonant transformers
  • circuit design, impedance matching
  • applications in Magnetic Particle Imaging

Curriculum Vitae

Fabian Mohn studied Electrical Engineering at the Hamburg University of Technology (TUHH) and he joined the group of Tobias Knopp for Biomedical Imaging at the University Medical Center Hamburg-Eppendorf (UKE) and the Hamburg University of Technology in 2020 as a PhD student. Working at Philips Research Laboratories Hamburg, he received his master's degree in 2018 on the Analysis and Optimization of the Signal-to-Noise Ratio for Receive Arrays in Magnetic Resonance Imaging.

Journal Publications

  • F. Mohn, F. Foerger, F. Thieben, M. Möddel, I. Schmale, T. Knopp and M. Graeser (2024). Resonant Inductive Coupling Network for Human-Sized Magnetic Particle Imaging. Review of Scientific Instruments. 95. (4), 044701 [Abstract] [doi]

  • F. Mohn, K. Scheffler, J. Ackers, A. Weimer, F. Wegner, F. Thieben, M. Ahlborg, P. Vogel, M. Graeser, and T. Knopp (2024). Characterization of the Clinically Approved MRI Tracer Resotran for Magnetic Particle Imaging in a Comparison Study. Physics in Medicine & Biology. 69. (13), 135014 [Abstract] [doi]

  • F. Thieben, F. Foerger, F. Mohn, N. Hackelberg, M. Boberg, J.-P. Scheel, Möddel, M. Graeser, and T. Knopp (2024). System Characterization of a Human-Sized 3D Real-Time Magnetic Particle Imaging Scanner for Cerebral Applications. Communications Engineering. 3. (1), 47 [Abstract] [doi]

  • F. Mohn, M. Exner, P. Szwargulski, M. Möddel, T. Knopp, and M. Graeser (2023). Saline bolus for negative contrast perfusion imaging in magnetic particle imaging. Physics in Medicine & Biology. 68. (17), 5026 [Abstract] [doi]

  • F. Mohn, P. Szwargulski, M. G. Kaul, M. Graeser, T. Mummert, K. M. Krishnan, T. Knopp, G. Adam, J. Salamon and C. Riedel (2023). Real-Time Multi-Contrast Magnetic Particle Imaging for the Detection of Gastrointestinal Bleeding. Scientific Reports. 13. (1), 22976 [Abstract] [doi]

  • F. Mohn, T. Knopp, M. Boberg, F. Thieben, P. Szwargulski, and M. Graeser (2022). System Matrix Based Reconstruction for Pulsed Sequences in Magnetic Particle Imaging. IEEE Transactions on Medical Imaging. 41. (7), 1862-1873 [Abstract] [doi] [www]

Conference Proceedings

  • F. Foerger, N. Hackelberg, M. Boberg, M. Möddel, F. Thieben, F. Mohn, and T. Knopp (2024). Single-Shot Magnetic Field Measurements for MPI. 13th International Workshop on Magnetic Particle Imaging (IWMPI 2024). 10. (1 Suppl 1), 1-1 [Abstract] [www] [BibTex]

  • F. Mohn, F. Foerger, F. Thieben, M. Möddel, T. Knopp, and M. Graeser (2024). Trade-off between Power Consumption and Receive Signal Strength for Inductively Coupled Transmit-Receive Circuits in MPI. 10. (1 Suppl 1), [Abstract] [doi] [BibTex]

  • F. Mohn, P. Szwargulski, M. G. Kaul, M. Graeser, T. Mummert, K. M. Krishnan, T. Knopp, G. Adam, J. Salamon, and C. Riedel (2024). In Vitro Detection of Gastrointestinal Bleeding Using Single- and Multi-Contrast MPI. 10. (1 Suppl 1), [Abstract] [doi] [BibTex]

  • F. Thieben, H. Albers, F. Mohn, F. Foerger, M. Boberg, K. Scheffler, M. Möddel, T. Kluth, and T. Knopp (2024). Experimental Parameter Calibration of the Scanner Model for Model-Based MPI. International Journal on Magnetic Particle Imaging. 10. (1 Suppl 1), 1-4 [Abstract] [doi] [www] [BibTex]

  • N. Hackelberg, M. Grosser, A. Tsanda, F. Mohn, K. Scheffler, M. Möddel, and T. Knopp (2024). RegularizedLeastSquares.jl: Modality Agnostic Julia Package for Solving Regularized Least Squares Problems. International Journal on Magnetic Particle Imaging. 10. (1 Suppl 1), 1-4 [Abstract] [doi] [BibTex]

  • F. Foerger, N. Hackelberg, M. Boberg, J.-P. Scheel, F. Thieben, L. Mirzojan, F. Mohn, M. Möddel, M. Graeser, and T. Knopp (2023). Flexible Selection Field Generation using Iron Core Coil Arrays. International Journal on Magnetic Particle Imaging. 9. (1), 1-4 [Abstract] [doi] [www] [BibTex]

  • F. Mohn, M. Exner, P. Szwargulski, M. Möddel, T. Knopp, and M. Graeser (2023). Using Negative Bolus in Dynamic MPI. International Journal on Magnetic Particle Imaging IJMPI. 9.(1). [Abstract] [doi] [www] [BibTex]

  • F. Niebel, J. Schumacher, F. Mohn, M. Ahlborg, T.M. Buzug, and M. Graeser (2023). A Novel Approach to FFL Trajectory Analysis. International Journal on Magnetic Particle Imaging IJMPI. 9.(1), [Abstract] [doi] [www] [BibTex]

  • F. Thieben, F. Mohn, F. Foerger, N. Hackelberg, J.-P. Scheel, M. Graeser, and T. Knopp (2023). Safe and Rapid 3D Imaging: Upgrade of a Human-Sized Brain MPI System. International Journal on Magnetic Particle Imaging. 9. (1 Suppl 1), 1-4 [Abstract] [doi] [www] [BibTex]

  • J. Ackers, F. Mohn, N. Hackelberg, T. Knopp, T.M. Buzug, and M. Graeser (2023). Model-based voltage predictions for arbitrary waveform excitation in Magnetic Particle Imaging. International Journal on Magnetic Particle Imaging IJMPI. 9.(1). [Abstract] [doi] [www] [BibTex]

  • K. Scheffler, F. Thieben, F. Mohn, M. Graeser, and T. Knopp (2023). MPI Signal Performance of Resotran. 12th International Workshop on Magnetic Particle Imaging (IWMPI 2023). 1-1 [Abstract] [www] [BibTex]

  • F. Foerger, J.-P. Scheel, F. Thieben, F. Mohn, T. Knopp, and M. Graeser (2022). Multi-Channel Current Control System for Coupled Multi-Coil Arrays. International Journal on Magnetic Particle Imaging. 8. (1), 1-3 [Abstract] [doi] [www] [BibTex]

  • F. Mohn, T. Knopp, and M. Graeser (2022). Role of Phase Encoding in Pulsed Magnetic Particle Imaging. International Journal on Magnetic Particle Imaging. 8.(1) [Abstract] [doi] [www] [BibTex]

  • F. Thieben, F. Foerger, F. Mohn, F. Sevecke, T. Knopp, and M. Graeser (2022). Heat it up: Thermal stabilization by active heating to reduce impedance drifts in capacitive matched networks. International Journal on Magnetic Particle Imaging. 8. (1), 1-3 [Abstract] [doi] [www] [BibTex]

Download this list as BibTeX file.